{"product_id":"jaquet-speed-sensor-dsf-1210-00-shv-5m-mpn-374z-05176","title":"Jaquet Speed Sensor DSF 1210.00 SHV Ex-Atex (5m) (MPN: 374Z-05176)","description":"\u003ch2\u003eJaquet DSF 1210.00 SHV Ex ATEX - Premium Industrial Hall Effect Speed Sensor\u003c\/h2\u003e\n\u003cp\u003eThe Jaquet DSF 1210.00 SHV Ex ATEX (374Z-05176) is a premium intrinsically safe Hall-effect speed sensor certified for use in explosive atmospheres. Featuring an M12x1 housing with 5m Teflon cable, this sensor generates speed-proportional frequency signals from 0.05 Hz with dynamic behavior for both static and near-static applications. ATEX certified for flammable gas and dust environments, it combines compact design with robust performance for hazardous area monitoring.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e DSF 1210.00 SHV Ex ATEX (5m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 374Z-05176\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrawing Number:\u003c\/strong\u003e 110428F1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e M12x1 thread, stainless steel X12CrNiS188 (material 1.4305)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Technology:\u003c\/strong\u003e Magnetically biased Hall device with trigger amplifier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 8-28 VDC (reverse polarity protected, max AC ripple 25 mVpp)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e Max 15 mA (without load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 0.05 Hz to 20 kHz (dynamic behavior with guaranteed pulse generation down to 0.05 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Tightening Torque:\u003c\/strong\u003e 12 Nm for M12x1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eATEX Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Atmospheres:\u003c\/strong\u003e II 2 G Ex ia IIC T6 Gb (Zone 1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDust Atmospheres:\u003c\/strong\u003e II 2 D Ex ia IIIC T155°C Db (Zone 21)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e EN 60079-0:2012+A11:2013 and EN 60079-11:2012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertificate:\u003c\/strong\u003e ZELM 03 ATEX 0124X (with supplements 1-4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Compliance:\u003c\/strong\u003e 2014\/30\/EU, IEC 61000-6-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotified Body:\u003c\/strong\u003e PRIMARA (ID 2572)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperating Temperature\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Environments:\u003c\/strong\u003e -20°C to variable maximum (dependent on electrical power and temperature class - see datasheet TABLE 1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDust Environments:\u003c\/strong\u003e -20°C to +100°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Class:\u003c\/strong\u003e T1 through T6 supported (varies with available electrical power)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Maximum operating temperature depends on sensor housing size, available electrical power from intrinsically safe supply, and Ex temperature class requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSignal Output\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Square wave from push-pull output stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Coupling:\u003c\/strong\u003e DC-coupled to supply (0V = reference voltage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Current:\u003c\/strong\u003e 25 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage HIGH:\u003c\/strong\u003e UHi \u0026gt; USupply - 4V (at Isource = 25 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage LOW:\u003c\/strong\u003e ULo \u0026lt; 2V (at Isink = 25 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Short-circuit proof and reverse polarity protected\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Voltage drop from cable impedance and safety barrier resistance must be considered\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Type:\u003c\/strong\u003e Teflon cable (Art. No. 824L-35053)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 5 meters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductors:\u003c\/strong\u003e 4-pole, 4 x 0.24 mm² (AWG 24)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Mesh screen, isolated from housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Diameter:\u003c\/strong\u003e Max 4.0 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e White\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e 60 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 32 g\/m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Brown wire is not used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Wheel Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Magnetically permeable material (e.g., Steel 1.0036)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreferred Type:\u003c\/strong\u003e Involute gear wheel (module 0.5 minimum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Tooth Width:\u003c\/strong\u003e 10 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSide Offset:\u003c\/strong\u003e \u0026lt; 0.2 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEccentricity:\u003c\/strong\u003e \u0026lt; 0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAir Gap Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule 1:\u003c\/strong\u003e 0.2 to 1.0 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule 2:\u003c\/strong\u003e 0.2 to 2.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule 3:\u003c\/strong\u003e 0.2 to 3.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule 4 and larger:\u003c\/strong\u003e 0.2 to 4.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Within specified air gap, output signal amplitude is not influenced by gap distance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP68 (sensor head), IP67 (cable connection)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Seal:\u003c\/strong\u003e Front side hermetically sealed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotting:\u003c\/strong\u003e Electronic components fully potted in chemical and age-resistant ceramic compound\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical Resistance:\u003c\/strong\u003e Resistant to oil, grease, and harsh industrial conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Immunity:\u003c\/strong\u003e 5 gn in the range 5-2000 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Immunity:\u003c\/strong\u003e 20 g during 20 ms, half-sine wave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e Housing, cable screen, and electronics galvanically separated (500V\/50Hz\/1 min)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Certified:\u003c\/strong\u003e Approved for Zone 1 gas and Zone 21 dust hazardous areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNear-Zero Speed Detection:\u003c\/strong\u003e Guaranteed pulse generation down to 0.05 Hz for static applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Behavior:\u003c\/strong\u003e Suitable for variable speed applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact M12x1 Design:\u003c\/strong\u003e Space-saving installation in tight locations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Quality Cable:\u003c\/strong\u003e Teflon insulation for chemical and temperature resistance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsically Safe:\u003c\/strong\u003e Type ia certification for maximum safety in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Maintenance Required:\u003c\/strong\u003e Sealed, non-serviceable design for long-term reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eIdeal for speed monitoring in explosive atmospheres including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil and gas production and processing facilities\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical plants\u003c\/li\u003e\n\u003cli\u003ePaint and solvent production areas\u003c\/li\u003e\n\u003cli\u003ePharmaceutical manufacturing in classified areas\u003c\/li\u003e\n\u003cli\u003eGrain handling and milling operations\u003c\/li\u003e\n\u003cli\u003eMining equipment in flammable atmospheres\u003c\/li\u003e\n\u003cli\u003eTurbomachinery in hazardous zones\u003c\/li\u003e\n\u003cli\u003eAny Zone 1 (gas) or Zone 21 (dust) classified location\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Solid and vibration-free mounting essential\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlignment:\u003c\/strong\u003e Sensor must be aligned to pole wheel according to sensor drawing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePositioning:\u003c\/strong\u003e Mount with middle of face over middle of pole wheel; minimum 3mm from wheel edge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Gap:\u003c\/strong\u003e Set smallest possible gap without risk of contact during operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Keep sensor wires away from large electrical machines; do not run parallel to power cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Barriers:\u003c\/strong\u003e Must be connected through appropriate Zener barriers for intrinsically safe operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Connection:\u003c\/strong\u003e Cable shield must be connected to 0V on equipment side\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety Notice\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage Condition:\u003c\/strong\u003e Sensor must be used in undamaged and clean condition only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModifications:\u003c\/strong\u003e Modifications prohibited unless expressly listed in operating instructions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Limitations:\u003c\/strong\u003e Permissible cable length and capacitance\/inductance limits per Certificate supplement must be observed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Monitoring:\u003c\/strong\u003e Surface temperature must not exceed 2\/3 of dust\/air mixture ignition temperature where dust clouds present\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Directives:\u003c\/strong\u003e Installation must comply with CE directives for explosive environment apparatus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background-color: #f8f9fa; padding: 15px; margin-top: 25px; border-left: 4px solid #007bff;\"\u003e\n\u003cp style=\"margin: 0; font-size: 0.9em;\"\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e This sensor is ATEX certified (ZELM 03 ATEX 0124X) for intrinsically safe operation in explosive atmospheres. Must be installed according to sensor drawing and used with appropriate certified safety barriers. The sensor cannot be repaired - replacement only. Available in 2m, 5m, and 10m cable lengths. Sensor is the same, cable can also be cut. Manufactured by TE Connectivity Sensors (Jaquet brand). For complete installation and safety requirements, refer to the full European Certificate of Conformity and supplements.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Jaquet","offers":[{"title":"Default Title","offer_id":56974554136908,"sku":"104-374Z-05176","price":1399.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1040\/6723\/6172\/files\/B2F4AAFE-5317-4AE4-8FC5-F55D9655FCB5_d80e236b-0209-495b-b173-416b5f1af408.png?v=1773426667","url":"https:\/\/mkcontrols.eu\/products\/jaquet-speed-sensor-dsf-1210-00-shv-5m-mpn-374z-05176","provider":"MKCONTROLS.EU","version":"1.0","type":"link"}