{"product_id":"sw180-4-albright-150a-200a-24v-co-1-pole-1-throw-contactor","title":"Albright SW180-4 DC Contactor 150A 24V – Continuous Duty","description":"\u003cdiv\u003e\n\u003ch2\u003eAlbright SW180-4 – 24V DC Continuous (CO) Solenoid Contactor, SPST-NO\u003c\/h2\u003e\n\u003cp\u003eThe Albright SW180-4 is a heavy‑duty DC contactor designed for reliable switching of motors and other DC loads. This single‑acting, single‑pole, normally‑open contactor features silver‑alloy double‑breaking tips for long life and low resistance, with a 24VDC continuous (100% duty) coil.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SW180 (single-acting)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil:\u003c\/strong\u003e 24 VDC, Continuous (100% duty)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e SPST, Normally Open (N\/O)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain terminals:\u003c\/strong\u003e M8 studs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil terminals:\u003c\/strong\u003e 6.3 mm spade connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e M5 tapped holes or optional steel bracket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation:\u003c\/strong\u003e Horizontal or vertical (studs up recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical applications:\u003c\/strong\u003e Forklifts, pallet movers, scissor lifts, tow tugs, golf carts, winches, EV conversions, industrial DC systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRatings \u0026amp; Performance\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterrupted: 150 A  |  Uninterrupted: 200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical voltage drop @150 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~30 mV (per pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity (UL583 guide)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 A (48 V DC) for SW180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 5 million operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil pull-in (typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 66% of rated coil voltage (continuous type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop-out (typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10–25% of rated coil voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (approx.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~0.64 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Albright SW180-4 contactor (24V DC, continuous)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote:\u003c\/em\u003e Mounting bracket and auxiliary contacts, if required, are sold separately.\u003c\/p\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cp\u003eCompact footprint for easy panel or chassis mounting. See manufacturer datasheet for detailed dimensions and drilling pattern.\u003c\/p\u003e\n\u003ch3\u003eCompatibility \u0026amp; Use\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for resistive, capacitive, and inductive DC loads\u003c\/li\u003e\n\u003cli\u003eCommon in OEM and aftermarket service for material handling and utility EVs\u003c\/li\u003e\n\u003cli\u003eCheck coil voltage (24 VDC) and current ratings against your application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse appropriately rated cable\/busbar and protective devices\u003c\/li\u003e\n\u003cli\u003eFor vertical mounting, orient with M8 studs upward (contact us if studs-down is required)\u003c\/li\u003e\n\u003cli\u003eObserve polarity if optional suppression or blowouts are used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Albright","offers":[{"title":"Default Title","offer_id":56974496334156,"sku":"101-SW180-4","price":65.0,"currency_code":"EUR","in_stock":true}],"url":"https:\/\/mkcontrols.eu\/products\/sw180-4-albright-150a-200a-24v-co-1-pole-1-throw-contactor","provider":"MKCONTROLS.EU","version":"1.0","type":"link"}