The Flash-Prevent prevents effectively the inadmissible flashing of LED lamps caused by the vehicle's pulsed cold scan ("hard" and short pulse ab. 10ms). The failure of an LED will be monitored.Attention! Flash-Prevent doesn't replace LED-ADAPT.▪ Prevents flashing of LED lamps▪ LED failure detection stays in function▪ Easy installation ahead of to the LED▪ possible to install inside the lamp housingWeight 27gEffectively prevents flashing of LED lamps
The failure detection stays in function
Easy installation due to compact dimensions
Easy installation ahead of to the LED lamps
Completes LED-ADAPT in combined monitoring
Operation
voltage:
24V nominal
Output current:
LED (max 0.4A)
Connection input:
strand with bare endings
Connection output:
strand with bare endings
Load imitation:
within 0-50ms cold filament
Cable length input:
0.30 m
Cable length output:
0.30 m
Temperature range:
-40...+75°C
Electrical protection:
__
Mechanical protection:
entirely sealed (IP69K)
Dimensions:
40 x 18 x 15 mm without cable outlet
Mass:
approx. 27g
Failure monitor LEDs:
integrated
Mounting rule:
__
The Flash-Prevent prevents effectively the inadmissible flashing of LED lamps caused by the vehicle's pulsed cold scan ("hard" and short pulse ab. 10ms). The failure of an LED will be monitored.Attention! Flash-Prevent doesn't replace LED-ADAPTER.▪ Prevents flashing of LED lamps▪ LED failure detection stays in function▪ Easy installation ahead of to the LED▪ possible to install inside the lamp housing
Weight: 0.03 kg
Effectively prevents flashing of LED lampsThe failure detection stays in functionEasy installation due to compact dimensionsEasy installation ahead of to the LED lampsCompletes LED-ADAPT in combined monitoring
Operation
voltage:
12V nominal
Output current:
LED (max 0.4A)
Connection input:
strand with bare endings
Connection output:
strand with bare endings
Load imitation:
within 0-50ms cold filament
Cable length input:
0.30 m
Cable length output:
0.30 m
Temperature range:
-40...+75°C
Electrical protection:
__
Mechanical protection:
entirely sealed (IP69K)
Dimensions:
40 x 18 x 15 mm without cable outlet
Mass:
approx. 27g
Failure monitor LEDs:
integrated
Mounting rule:
__
HI-FLEX is a high quality flexible multi-strand class 6 cable
This flexible and multi-strand cable is suitable for welding cable, vehicle use, starter cable, and solar panel installations for example.
Oil resistant PVC cable
Wire of fine-grained annealed copper
Temperature range -30 ... + 70 ° C
SBS 50 -series Anderson connector, housing only. Use it as a spare.
Polycarbonate housings feature 2 positions all finger proof. Genderless design mates with itself. Mechanical keys are color coded.
The patented SBS® connector family is designed to provide high power in a compact ergonomic housing with protection against accidental contact with live circuits.
This is of particular importance in applications where DC voltages exceed 30 volts and can be health threatening.
Wire-to-wire and wire-to-board configurations both provide power contacts rated up to 110 amps.
The SBS®75X offers up to 4 mate-last break-first auxiliary power / signal contacts rated up to 20 amps.
The SBS®75G features a third first-mate last-break ground or power contact.
All contact positions are rated for circuit interruption (hot plugging).
Touch Safe Interface can safely be used in through panel applications and minimizes potential contact with live circuits per IEC 60950
Wire-to-Wire and Wire-to-Board Configurations Allows one connector to meet multiple needs
Ground or Auxiliary Positions Integrated into the One Piece Housing Meets all connection requirements in one compact connector housing
Compact 12V Rotary Hammer: Key Features
This is the industry’s first brushless 12V rotary hammer, delivering 1.1 Joules of impact energy and up to 900 rpm with 6575 impacts per minute. It features an exceptionally low vibration level of 4.4 m/s², allowing for extended daily use. The POWERSTATE™ motor offers 3x longer life, with up to 60 holes drilled per battery charge. The tool supports both rotary hammer and rotation-only modes, optimized for drilling 6-10 mm, with a max capacity of 13 mm in concrete. Compatible with M12™ batteries and dust extractors.
Specifications:
• Voltage: 12V
• Impact Energy: 1.1 J
• Weight: 1.5 kg (without battery)
Tool only, without battery or charger.
REMA DIN 640 Handle
Fits both REMA DIN 640 Plug and Socket
REMA ITEM 108994/95800-11Includes:DIN 640 A handle, acid resistant4 screws + 4 nuts
Single packed in a ZIP-bag
Heavy-Duty DC Reversing Contactor 12 V – Replacement for Lewmar DC66-46P
This heavy-duty 12 V DC reversing contactor is designed as a direct functional replacement for the Lewmar DC66-46P changeover contactor. Engineered for demanding marine and industrial applications, it delivers enhanced durability, improved corrosion resistance, and a longer service life compared to standard units.
Key Features
Direct replacement for Lewmar DC66-46P
High-performance contact design for extended switching life
Sealed housing provides protection against moisture and salt spray
12 V DC coil voltage – ideal for marine windlass and thruster systems
Compact footprint for easy drop-in installation
Heavy-duty silver-alloy contacts ensure reliable current handling
Technical Highlights
Coil Voltage: 12 V DC
Current Rating: 250 A continuous / 1000 A peak
Contact Configuration: Double-pole, double-throw (reversing)
Environmental Protection: IP66-equivalent sealed enclosure
Operating Temperature: −25 °C to +85 °C
Compatibility
This contactor is fully compatible with systems originally equipped with the Lewmar DC66-46P. It can be installed using the same wiring configuration and mounting pattern.
Lewmar® is a registered trademark of Lewmar Limited. This product is an independent aftermarket replacement selected from the Albright International contactor range — widely regarded for its exceptional quality and reliability in demanding marine and industrial applications. It is not manufactured or endorsed by Lewmar, but supplied by OEM Nordic as a premium alternative for maintenance and service use.
Applications
Windlass and thruster motor control
Hydraulic pump systems
Industrial DC motor reversing